Room air entrainment during beta-agonist delivery with heliox
Sunil Dhuper1, Sonia Choksi, Simdararajan Selvaraj
1North Central Bronx Hospital, Medicine, 3424 Kossuth Ave, Bronx, NY 10467, USA. sunil.dhuper@nychhc.org
Abstract:
Studies of the efficacy of heliox in patients with severe asthma have shown mixed results. Among the factors that are responsible for variable outcomes, the failure of heliox delivery systems to prevent room air entrainment (RAE) during beta-agonist delivery is probably the most critical. While keeping the rotameter flow rate (FR) of heliox mixed 70:30 to a nebulizer at 10 L/min, the FR of heliox from a second gas source to a T-connector (TC) was increased during the delivery of the beta-agonist with a conventional T-nebulizer delivery system (TNDS). A negative peak inspiratory flow (pneumotachometer reading) or a helium concentration of < 70% (quadralizer reading) were indicators of RAE. RAE was tested during spontaneous tidal breathing and acute asthma. A rotameter FR of 10 L/m to the nebulizer with no flow from a second gas source to a TC (conventional TNDS) resulted in a significant drop in helium concentration during tidal breathing (46.2%) and acute asthma (27.5%) due to RAE. This degree of helium dilution can negate the beneficial effects of heliox to lung mechanics almost completely. A rotameter FR of 10 L/m each to a nebulizer and a TC resulted in a helium concentration 69.8% during tidal breathing (no RAE), but 49% (significant RAE) during asthma events. A rotameter FR of 15 L/m (pressure regulator setting, 100 lbs per square inch) to a TC, while maintaining a rotameter FR of 10 L/m to a nebulizer prevented RAE during asthma (helium concentration, 69.9%). Conventional TNDS may be used to deliver the beta-agonist with heliox during asthma without RAE.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...