Related Experiment Video
Updated: Jul 19, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome
Pier Paolo Terragni1, Giulio Rosboch, Andrea Tealdi
1Università di Torino, Dipartimento di Anestesiologia e Rianimazione, Ospedale S. Giovanni Battista-Molinette, Corso Dogliotti 14, 10126 Turin, Italy.
Rationale:
Tidal volume and plateau pressure limitation decreases mortality in acute respiratory distress syndrome. Computed tomography demonstrated a small, normally aerated compartment on the top of poorly aerated and nonaerated compartments that may be hyperinflated by tidal inflation.
Objectives:
We hypothesized that despite tidal volume and plateau pressure limitation, patients with a larger nonaerated compartment are exposed to tidal hyperinflation of the normally aerated compartment.
Measurements And Main Results:
Pulmonary computed tomography at end-expiration and end-inspiration was obtained in 30 patients ventilated with a low tidal volume (6 ml/kg predicted body weight). Cluster analysis identified 20 patients in whom tidal inflation occurred largely in the normally aerated compartment (69.9 +/- 6.9%; "more protected"), and 10 patients in whom tidal inflation occurred largely within the hyperinflated compartments (63.0 +/- 12.7%; "less protected"). The nonaerated compartment was smaller and the normally aerated compartment was larger in the more protected patients than in the less protected patients (p = 0.01). Pulmonary cytokines were lower in the more protected patients than in the less protected patients (p < 0.05). Ventilator-free days were 7 +/- 8 and 1 +/- 2 d in the more protected and less protected patients, respectively (p = 0.01). Plateau pressure ranged between 25 and 26 cm H(2)O in the more protected patients and between 28 and 30 cm H(2)O in the less protected patients (p = 0.006).
Conclusions:
Limiting tidal volume to 6 ml/kg predicted body weight and plateau pressure to 30 cm H(2)O may not be sufficient in patients characterized by a larger nonaerated compartment.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-IV
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...