Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
The effectiveness of a high output/short duration radiofrequency current application technique in segmental pulmonary
Brian Nilsson1, Xu Chen, Steen Pehrson
1Medical Department B, Department of Cardiology, The Heart Centre, Cardiac Catheterization Laboratory, Rigshospitalet, Copenhagen University Hospital, 9 Blegdamsvej, DK-2100 Copenhagen, Denmark. brni@dadlnet.dk
Aims:
Segmental pulmonary vein (PV) isolation by radiofrequency (RF) catheter ablation has become a curative therapy for atrial fibrillation (AF). However, the long procedure time limits the wide application of this procedure. The aim of the current study was to compare a novel ablation technique with a high power output and short application time vs. a conventional technique using a low power output and long application time.
Methods And Results:
The study included 90 consecutive patients (age 53+/-10 years; 66 men). Segmental PV isolation was performed by irrigated RF catheter ablation in both groups. In the conventional group (Group 1, 45 patients), the power output was limited to 30 W with a target temperature of 50 degrees C and an RF preset duration of 120 s. In the novel group (Group 2, 45 patients), the maximum power output was preset to 45 W, with a target temperature of 55 degrees C and duration of 20 s. In Group 2, a significant reduction in the PV isolation time (127+/-57 vs. 94+/-33 min, P<0.02), mean fluoroscopy time (73+/-23 vs. 55+/-16 min, P<0.001), and radiation dose was observed. According to the application time and number, Group 2 showed a reduction in RF application time, but a higher number of RF applications were required for creation of complete PV isolation. During a mean follow-up of 15+/-7 months, a total of 74% of patients in Group 1 and 76% of patients in Group 2 demonstrated stable SR.
Conclusion:
Segmental PV isolation using a high power output and short application time is safe and effective in PV isolation in patients with AF. This technique can significantly reduce the procedure and fluoroscopy time compared with a low-power output technique.
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...