Curcumin content of turmeric and curry powders

Reema F Tayyem1, Dennis D Heath, Wael K Al-Delaimy

  • 1Clinical Nutrition and Dietetics Department, Allied Health Sciences Faculty, The Hashemite University, Jordan.

Nutrition and Cancer
|October 19, 2006
PubMed

Related Concept Videos

Therapeutic Index01:13

Therapeutic Index

The therapeutic index of a drug is a key parameter in pharmacology that quantifies the relative safety of a drug by calculating the ratio between the dose that causes toxicity in half the population (50%) to the dose that proves to be effective for half the population (50%). It provides a spectrum of doses for a particular drug ranging from effective to potentially toxic. To illustrate, consider an anticoagulant agent like warfarin. It possesses a narrow window within its therapeutic index to...
IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Complexometric EDTA Titration Curves01:20

Complexometric EDTA Titration Curves

EDTA titration curves determine the free metal ion concentration. The titration curve represents the change in concentration of free metal ions (p function) as a function of the volume of EDTA added. This curve consists of three regions: before, at, and after equivalence points. Excess free metal ions are present before the equivalence point. Equal concentrations of metal ions and EDTA are present at the equivalence point. After the equivalence point, excess EDTA exists. This means slight...
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the other increases, and...
NMR Spectroscopy of Aromatic Compounds01:14

NMR Spectroscopy of Aromatic Compounds

Aromatic compounds can be identified or analyzed using proton NMR and carbon‐13 NMR. Typically, aromatic hydrogens or hydrogens directly bonded to the aromatic rings are strongly deshielded by the aromatic ring current. Therefore, they absorb in the range of 6.5–8.0 ppm in proton NMR spectra. For instance, aromatic hydrogens directly bonded to the benzene ring absorb at 7.3 ppm. However, aromatic hydrogens of larger rings absorb farther upfield or downfield than the ideal range. Consider...
Turnover Number and Catalytic Efficiency01:19

Turnover Number and Catalytic Efficiency

The turnover number of an enzyme is the maximum number of substrate molecules it can transform per unit time. Turnover numbers for most enzymes range from 1 to 1000 molecules per second. Catalase has the known highest turnover number, capable of converting up to 2.8×106 molecules of hydrogen peroxide into water and oxygen per second. Lysozyme has the lowest known turnover number of half a molecule per second.
Chymotrypsin is a pancreatic enzyme that breaks down proteins during digestion. The...