A simplified method for continuous hepatic arterial port-catheter system placement not requiring catheter end-hole
1Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan. yamagami@koto.kpu-m.ac.jp
Purpose:
To evaluate the efficacy of hepatic port-catheter system placement without distal catheter tip occlusion or gastroduodenal artery embolization distal to the catheter tip.
Material And Methods:
A port-catheter system was percutaneously implanted in 29 patients (16 men, 13 women; mean age 65.6 years) with unresectable liver cancer. Persistent blood flow through the end hole of the catheter was verified immediately and 1-10 days after catheter placement.
Results:
In all cases, percutaneous port-catheter placement was successfully performed. In seven of 29 (24.1%) patients, flow through the end hole of the catheter was verified immediately after the procedure. However, no flow was seen 1-10 days after the procedure.
Conclusion:
It is not necessary to occlude the end hole of the catheter tip and embolize the gastroduodenal artery beyond the catheter tip when placing a port-catheter system for repeated hepatic arterial infusion chemotherapy.