A Fitzpatrick1, G Theodorakis, R Ahmed
1Cardiac Department, Westminster Hospital, London, England.
Abstract:
To determine if pacing might prevent syncope in cardioinhibitory 'Malignant Vasovagal Syndrome' (also known as 'Neurally-Mediated Bradycardia/Hypotension'), a study of dual chamber pacing during head-up 60 degrees tilt was undertaken. Paired invasive tilts were performed in 10 patients who had a history of recurrent syncope, normal routine investigations including electrophysiological study and prior tilt-induced vasovagal syncope. Vasovagal reactions of identical severity were produced by prolonged 60 degrees head-up tilt on consecutive days in seven out of 10 patients. On day 2, without pacing, seven patients had tilt-induced vasovagal reactions and six became syncopal during the reaction. On day 3, with temporary DVI pacing with rate hysteresis, seven patients had tilt-induced vasovagal reactions and 1 patient was syncopal. Syncope was aborted in the other five patients. DVI pacing significantly improved cardiac index (CI) (one +/- 0.2 to 1.6 +/- 0.3 L/min/m2, P less than 0.01) and mean arterial blood pressure (MABP) (30 +/- 11 to 48 +/- 12 mmHg, P less than 0.01) during vasovagal reactions on day 3 compared with day 2. The mean period of time that patients could tolerate in the tilted position after the onset of the tilt-induced vasovagal reaction was significantly prolonged by pacing from 0.9 +/- 1.2 to 3.2 +/- 1.6 min (P less than 0.01). Dual chamber pacing may abort syncope in 85% of patients with cardioinhibitory malignant vasovagal syndrome. Pacing may prolong consciousness sufficiently during a vasovagal reaction to allow injury to be avoided.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias VI: Management of Dysrhythmias
Cardiopulmonary Resuscitation IV: Pharmacological Management
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias