A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water
Jun-Xia Wang1, Dong-Qing Jiang, Zhi-Yuan Gu
1Key Laboratory of Functional Polymer Materials, Ministry of Education, Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin 300071, China.
Abstract:
Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...