Related Experiment Video
Updated: Jul 19, 2026

Invasive Hemodynamic Assessment for the Right Ventricular System and Hypoxia-Induced Pulmonary Arterial Hypertension in Mice
Published on: October 24, 2019
Variations in arterial blood pressure and photoplethysmography during mechanical ventilation
Giuseppe Natalini1, Antonio Rosano, Maria E Franceschetti
1Department of Anesthesia, Intensive Care and Emergency, Poliambulanza Hospítal, Brescí, Italy. natalini-giuseppe@poliambulanza.it
Abstract:
We analyzed ventilation-induced changes in arterial blood pressure and photoplethysmography from waveforms obtained by monitoring 57 patients in the operating room and intensive care unit. Analysis of systolic and pulse pressure variations during positive pressure ventilation, DeltaUp, DeltaDown, and changes in the preejection period on both arterial and photoplethysmographic waveforms were possible in 49 (86%) patients. The pulse pressure variation and preejection period were similar when calculated using both arterial blood pressure and photoplethysmography, whereas the other variables were different. Photoplethysmographic pulse variation >9% identified patients with arterial pulse pressure variation >13% (area under ROC curve = 0.85) or DeltaDown >5 mm Hg (area under ROC curve = 0.85). In hypotensive patients, photoplethysmographic pulse variation >9% remained the best threshold value (pulse pressure variation >13%: area under ROC curve = 0.90; DeltaDown >5 mm Hg: area under ROC curve = 0.93) for predicting fluid responsiveness. In conclusion, this study showed that pulse variations observed in the arterial pressure waveform and photoplethysmogram are similiar in response to positive pressure ventilation. Furthermore, photoplethysmographic pulse variation > 9% identifies patients with ventilation-induced arterial blood pressure variation that is likely to respond to fluid administration.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...