Related Experiment Video
Updated: Jun 30, 2026

An Improved Method for Rapid Intubation of the Trachea in Mice
Published on: February 22, 2016
The effect of tracheal gas insufflation on gas exchange efficiency
Michael R Pinsky1, Edgar Delgado, Bernard Hete
1Cardiopulmonary Research Laboratory, Department of Critical Care Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15261, USA. pinskymr@upmc.edu
Abstract:
Transtracheal gas insufflation (TGI) improves gas exchange efficiency, but is associated with hyperinflation, and usually requires ventilator adjustment to compensate for the increased gas flow. Although bidirectional TGI (Bi-TGI) minimizes hyperinflation, it does not preclude the need to reduce tidal volumes to prevent hyperinflation. A flow-compensation system was developed by Respironics (Murrysville, PA) to match TGI flows; however, neither that nor the efficacy of Bi-TGI have been tested in vivo. We tested the hypotheses that flow compensation allows for a constant minute ventilation; Bi-TGI produces less hyperinflation than does unidirectional TGI (Uni-TGI), and endotracheal tube size influences the degree of hyperinflation during TGI. Seven anesthetized intact dogs were studied during positive-pressure ventilation using the Respironics flow compensation system. Measurements were made during steady-state conditions at constant and measured levels of CO(2) production. Gas exchange efficiency (assessed by expired gas analysis for dead space) and hyperinflation (measured as an increase in pleural pressure) were compared during Bi- and Uni-TGI and for endotracheal tube sizes varying from 7 to 10F. Bi- and Uni-TGI could be delivered at constant minute ventilation without adjusting ventilatory setting when the flow compensation circuit was present. Uni-TGI produced more hyperinflation than did Bi-TGI with all sizes of endotracheal tube, and hyperinflation was universally present as tube size decreased to 7.5F. We conclude that this new flow compensation system allows for the delivery of TGI without the need for adjustments to the ventilator settings, and that Bi-TGI produces less hyperinflation than does Uni-TGI, even with small diameter endotracheal tubes.
More Related Videos
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Physical Principles Governing Gas Exchange
Gas Laws Governing Respiration
The behavior of gases is guided by Dalton's Law of partial pressures and Henry's Law.
Dalton's Law asserts that the total pressure exerted by...
External and Internal Respiration
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Atelectasis II: Pathophysiology

