Related Experiment Video
Updated: Jul 19, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Diagnostic value of D-dimer in patients with suspected pulmonary embolism: results from a multicentre outcome study
Florence Parent1, Sophie Maître, Guy Meyer
1Hôpital Antoine Béclère, Assistance Publique Hôpitaux de Paris, Clamart, France.
Background:
D-dimer tests are used in various diagnostic strategies to exclude pulmonary embolism (PE). However, their role as an exclusionary first-line test is still uncertain, mainly because accuracy of the test varies according to the assay and the studied population.
Methods:
The aim of this multicentre study was to evaluate the accuracy of D-dimer testing in patients with suspected PE. Diagnosis of PE was based on pre-test clinical probability (PCP) evaluation and both single-detector spiral CT (CT) and lower limbs compression ultrasonography (CUS). Lung scanning and/or pulmonary angiography was mandatory when CT or CUS was inconclusive and when both CT and CUS were normal in a patient with a high PCP. All patients were followed-up for 3 months, looking for VTE recurrence. D-dimers were collected within 24 h of inclusion and stored in each local hematology unit, to be analyzed at the end of all inclusions; physicians in charge of the patient were blinded to D-dimer results.
Results:
Three hundred and fifty two patients were included in 4 centres. Prevalence of PE was 38.6%. PCP was low in 82 (23.3%), intermediate in 176 (50%) and high in 94 (26.7%) patients. Sensitivity of D-dimer was 96.3% (95% CI: 93-99) and negative predictive value reached 94.4% (95% CI: 90-99). Five patients with a confirmed PE had a D-dimer level below 500 ng/ml (two patients with a high PCP). Among 258 patients with low or intermediate PCP, 80 (31%) had a negative D-dimer test result; three of them had a false negative result and the number needed to test was 3.3. Among 94 patients with a high PCP, 9 had a negative D-dimer test result; two of them had a false negative result and the number needed to test was 13.5.
Conclusion:
These results confirm that rapid assays used in this study can safely exclude PE in first-line testing only in non-high CP patients.
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Pulmonary Embolism I: Introduction
Pulmonary Embolism III: Nursing Management
Acute Coronary Syndrome III: Diagnostic Studies