Nonlinear ultrasound propagation through layered liquid and tissue-equivalent media: computational and experimental
Ross Williams1, Emmanuel Cherin, Toby Y J Lam
1Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 3M5, Canada. williams@sri.utoronto.ca
Abstract:
Nonlinear propagation has been demonstrated to have a significant impact on ultrasound imaging. An efficient computational algorithm is presented to simulate nonlinear ultrasound propagation through layered liquid and tissue-equivalent media. Results are compared with hydrophone measurements. This study was undertaken to investigate the role of nonlinear propagation in high frequency ultrasound micro-imaging. The acoustic field of a focused transducer (20 MHz centre frequency, f-number 2.5) was simulated for layered media consisting of water and tissue-mimicking phantom, for several wide-bandwidth source pulses. The simulation model accounted for the effects of diffraction, attenuation and nonlinearity, with transmission and refraction at layer boundaries. The parameter of nonlinearity, B/A, of the water and tissue-mimicking phantom were assumed to be 5.2 and 7.4, respectively. The experimentally measured phantom B/A value found using a finite-amplitude insert-substitution method was shown to be 7.4 +/- 0.6. Relative amounts of measured second and third harmonic pressures as a function of the fundamental pressures at the focus were in good agreement with simulations. Agreement within 3% was found between measurements and simulations of the beam widths of the fundamental and second harmonic signals following propagation through the tissue phantom. The results demonstrate significant nonlinear propagation effects for high frequency imaging beams.
More Related Videos
10:39Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
07:38Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU)
Published on: November 3, 2015
Related Concept Videos
Deriving the Speed of Sound in a Liquid
The speed of sound in fluids can be derived by considering a mechanical wave propagating...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Speed of Sound in Solids and Liquids
Propagation of Waves
Consider a scenario where a wave propagates from a string of low linear mass density to a string of high linear mass density. In such a case, the reflected wave is out of phase with respect to the incident wave, however the...
Imaging Studies II: Ultrasonography