Related Experiment Video
Updated: Jul 19, 2026

Automated Measurement of Pulmonary Emphysema and Small Airway Remodeling in Cigarette Smoke-exposed Mice
Published on: January 16, 2015
Air pollution in Boston bars before and after a smoking ban
James L Repace1, James N Hyde, Doug Brugge
1Department of Public Health and Family Medicine, Tufts University School of Medicine, Boston, MA 02111, USA. repace@comcast.net
Background:
We quantified the air quality benefits of a smoke-free workplace law in Boston Massachusetts, U.S.A., by measuring air pollution from secondhand smoke (SHS) in 7 pubs before and after the law, comparing actual ventilation practices to engineering society (ASHRAE) recommendations, and assessing SHS levels using health and comfort indices.
Methods:
We performed real-time measurements of respirable particle (RSP) air pollution and particulate polycyclic aromatic hydrocarbons (PPAH), in 7 pubs and outdoors in a model-based design yielding air exchange rates for RSP removal. We also assessed ventilation rates from carbon dioxide concentrations. We compared RSP air pollution to the federal Air Quality Index (AQI) and the National Ambient Air Quality Standard (NAAQS) to assess health risks, and assessed odor and irritation levels using published SHS-RSP thresholds.
Results:
Pre-smoking-ban RSP levels in 6 pubs (one pub with a non-SHS air quality problem was excluded) averaged 179 microg/m3, 23 times higher than post-ban levels, which averaged 7.7 microg/m3, exceeding the NAAQS for fine particle pollution (PM2.5) by nearly 4-fold. Pre-smoking ban levels of fine particle air pollution in all 7 of the pubs were in the Unhealthy to Hazardous range of the AQI. In the same 6 pubs, pre-ban indoor carcinogenic PPAH averaged 61.7 ng/m3, nearly 10 times higher than post-ban levels of 6.32 ng/m3. Post-ban particulate air pollution levels were in the Good AQI range, except for 1 venue with a defective gas-fired deep-fat fryer, while post-ban carcinogen levels in all 7 pubs were lower than outdoors.
Conclusion:
During smoking, although pub ventilation rates per occupant were within ASHRAE design parameters for the control of carbon dioxide levels for the number of occupants present, they failed to control SHS carcinogens or RSP. Nonsmokers' SHS odor and irritation sensory thresholds were massively exceeded. Post-ban air pollution measurements showed 90% to 95% reductions in PPAH and RSP respectively, differing little from outdoor concentrations. Ventilation failed to control SHS, leading to increased risk of the diseases of air pollution for nonsmoking workers and patrons. Boston's smoking ban eliminated this risk.
More Related Videos
09:50Impact Assessment of Repeated Exposure of Organotypic 3D Bronchial and Nasal Tissue Culture Models to Whole Cigarette Smoke
Published on: February 12, 2015
10:47Isolation of Mouse Respiratory Epithelial Cells and Exposure to Experimental Cigarette Smoke at Air Liquid Interface
Published on: February 21, 2011
Related Concept Videos
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Stress Prevention and Stress Management Techniques IV
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Other Pulmonary Disorders