Polydioxanone sternal sutures for prevention of sternal dehiscence
Nicola Luciani1, Amedeo Anselmi, Fabrizio Gandolfo
1Department of Cardiovascular Medicine, Division of Cardiac Surgery, Catholic University of the Sacred Heart, Largo A. Gemelli 8, 00168 Rome, Italy. nicola.luciani@tiscalinet.it
Background:
Sternal dehiscence and wound instability are troublesome complications following median sternotomy. Classic sternal approximation with stainless steel wires may not be the ideal approach in patients predisposed to these complications. We tested the efficacy of polydioxanone (PDS) suture in sternal closure and in prevention of complications in comparison to steel wires in high-risk individuals.
Methods:
Three hundred sixty-six patients undergoing elective cardiac surgery with full median sternotomy and having body surface area (BSA) less than 1.5 m(2) were randomly assigned to receive PDS (n = 181) or stainless steel (SS, n = 185) sternal approximation. The study was focused on aseptic sternal complications, namely bone dehiscence and superficial wound instability.
Results:
Both bone dehiscence and superficial wound instability were less frequent in the PDS Group (4 and 3 cases in the SS Group, respectively, vs. no cases in the PDS Group). Cox proportional hazards regression model in the whole study population identified female sex, chronic renal insufficiency, diabetes, advanced age, lower sternal thickness, osteoporosis, corticosteroid therapy, and prolonged CPB or ventilation times as predisposing factors to any of the two studied sternal complications.
Discussion:
Data suggest that PDS suture can protect against development of aseptic sternal complications following median sternotomy in high-risk patients with little body mass. The adoption of PDS in other subsets of patients, i.e., obese individuals, is to be questioned.
More Related Videos
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...