Related Experiment Video
Updated: Jul 19, 2026

Using Retinal Imaging to Study Dementia
Published on: November 6, 2017
[Time-multiplexing stereophotography: 2D and 3D qualitative and semiquantitative evaluation of glaucomatous optic
M V Lehmann1, C Y Mardin, B Lausen
1Département d'Ophtalmologie, Université d'Erlangen, Nürnberg, Allemagne. marina.lehmann@gmx.net
Purpose:
Real color documentation of the optic nerve head (ONH) is one of the most important methods in identifying early progression of glaucomatous optic nerve damage. This study qualitatively and semiquantitatively compared the evaluation of ONH photographs, using a 3D time-multiplexing system and conventional 2D photography, visualized on a computer monitor.
Patients And Methods:
Twelve 15 degrees sequential stereophotographs from the Erlangen Glaucoma Registry were scanned by a SprintScan 35 Plus Film scanner (Polaroid, Waltham, MA, USA) and converted by computer software (3D-PIX, NuVision, McNaughton Inc., Beaverton, OR, USA) in jps format (3D). The same ONH images were shown in 2D and 3D to 22 subjects: 12 residents and ten ophthalmologists and evaluated using a standardized questionnaire.
Results:
We observed a significantly better evaluation with stereoscopic pictures for both qualitative parameters (cup depth, visibility of the retinal nerve fibers, and the thinnest location of the neuroretinal rim) and quantitative parameters (c/d ratio and size of the disc, depending on the training level: in 3D better evaluation by the residents, in 2D by the ophthalmologists). With 2D pictures, we found better evaluation of the B zone and the stage of atrophy. Other than the method used for the entire evaluation, there was no significant difference between the groups. For the parameters weighed for clinical importance, the score of correct answers was significantly better with stereoscopic pictures.
Conclusion:
This study showed a significantly better evaluation of glaucomatous ONH atrophy with 3D images than with 2D pictures, independently of the evaluators' clinical training level. The computer-based evaluation of ONH atrophy using a time-multiplexing system (shutter glasses) may improve the diagnosis of glaucoma patients.
More Related Videos
07:11Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
12:48In Vivo Dynamics of Retinal Microglial Activation During Neurodegeneration: Confocal Ophthalmoscopic Imaging and Cell Morphometry in Mouse Glaucoma
Published on: May 11, 2015