Related Experiment Video
Updated: Jul 19, 2026

Cardiac Response to β-Adrenergic Stimulation Determined by Pressure-Volume Loop Analysis
Published on: May 19, 2021
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
David Osman1, Christophe Ridel, Patrick Ray
1Service de Réanimation Médicale, Centre Hospitalo-Universitaire de Bicêtre, Assistance Publique-Hôpitaux de Paris, Université Paris XI, Le Kremlin-Bicêtre, France.
Objective:
Values of central venous pressure of 8-12 mm Hg and of pulmonary artery occlusion pressure of 12-15 mm Hg have been proposed as volume resuscitation targets in recent international guidelines on management of severe sepsis. By analyzing a large number of volume challenges, our aim was to test the significance of the recommended target values in terms of prediction of volume responsiveness.
Design:
Retrospective study.
Setting:
A 24-bed medical intensive care unit.
Patients:
All consecutive septic patients monitored with a pulmonary artery catheter who underwent a volume challenge between 2001 and 2004.
Intervention:
None.
Measurements And Main Results:
A total of 150 volume challenges in 96 patients were reviewed. In 65 instances, the volume challenge resulted in an increase in cardiac index of > or =15% (responders). The pre-infusion central venous pressure was similar in responders and nonresponders (8 +/- 4 vs. 9 +/- 4 mm Hg). The pre-infusion pulmonary artery occlusion pressure was slightly lower in responders (10 +/- 4 vs. 11 +/- 4 mm Hg, p < .05). However, the significance of pulmonary artery occlusion pressure to predict fluid responsiveness was poor and similar to that of central venous pressure, as indicated by low values of areas under the receiver operating characteristic curves (0.58 and 0.63, respectively). A central venous pressure of <8 mm Hg and a pulmonary artery occlusion pressure of <12 mm Hg predicted volume responsiveness with a positive predictive value of only 47% and 54%, respectively. With the knowledge of a low stroke volume index (<30 mL.m), their positive predictive values were still unsatisfactory: 61% and 69%, respectively. When the combination of central venous pressure and pulmonary artery occlusion pressure was considered instead of either pressure alone, the degree of prediction of volume responsiveness was not improved.
Conclusion:
Our study demonstrates that cardiac filling pressures are poor predictors of fluid responsiveness in septic patients. Therefore, their use as targets for volume resuscitation must be discouraged, at least after the early phase of sepsis has concluded.
Related Concept Videos
Heart Failure II: Pathophysiology
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Measurement of Blood Pressure
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Hormonal Regulation of Blood Pressure
Epinephrine and Norepinephrine
The adrenal medulla releases epinephrine and norepinephrine, catecholamines that enhance and extend the sympathetic or "fight or flight" physiological response. These hormones escalate heart rate and the force of contraction while...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

