Simple detection of small amounts of Pseudomonas cells in milk by using a microfluidic device
1Graduate School of Pharmaceutical Sciences, Osaka University, Suita, Osaka, Japan.
Aims:
Flow cytometry offers rapid and reliable analyses of bacteria in milk. However, a flow cytometer is relatively expensive and operation is rather complicated for an unskilled operator. We applied flow cytometry using a microfluidic device (on-chip flow cytometry) in detection of small amounts of milk-spoiling bacteria.
Methods And Results:
Pseudomonas cells in milk were in situ hybridized with Cy5-labelled probe specific for Pseudomonas spp. under optimized condition. Numbers of Pseudomonas cells in the stationary phase and in the starved state determined by on-chip flow cytometry were compared with those determined by conventional plate counting, and on-chip flow cytometry detected targeted cells in milk that were undetectable as colony forming units(CFU) on Standards Methods Agar.
Conclusions:
The contamination in milk with fewer than 10 CFU ml(-1) of targeted cells in starved state was detectable with simple procedure (0.5 h milk-clearing, 1 h fixation, 2 h hybridization and 0.5 h on-chip flow cytometry following 12 h enrichment of cells).
Significance And Impact Of The Study:
On-chip flow cytometry following fluorescence in situ hybridization could be applicable to simple detection of milk-spoiling bacteria.