Related Experiment Video
Updated: Jul 19, 2026

A Periprosthetic Joint Candida albicans Infection Model in Mouse
Published on: February 2, 2024
Risk of infection with an antibiotic coated penile prosthesis at device replacement for mechanical failure
Robert Abouassaly1, Kenneth W Angermeier, D K Montague
1Glickman Urological Institute A/100, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA.
Purpose:
The inflatable penile prosthesis is well established as an effective treatment for select patients with organic erectile dysfunction. The risk of prosthetic infection at primary implantation is approximately 2%. However, for revision or replacement procedures the risk of infection has been reported to be as high as 13.3%. To minimize the overall risk of prosthetic infection an antibiotic coated inflatable penile prosthesis (InhibiZone) has been developed. To assess the impact on infection rates we reviewed our experience with the use of this device at prosthesis replacement for mechanical failure.
Materials And Methods:
We retrospectively reviewed the records of all patients undergoing inflatable penile prosthesis replacement for mechanical failure with an antibiotic coated prosthesis between May 2001 and November 2004. Salvage procedures for clinically infected prostheses were excluded from analysis. Chart review was performed with examination of operative notes, all postoperative contacts and microbiological data.
Results:
A total of 55 patients underwent replacement of an inflatable penile prosthesis for mechanical failure using a device coated with rifampin and minocycline HCL (InhibiZone). In all patients before reimplantation component spaces were irrigated in standard fashion. With a median followup of 32 months (range 12 to 54) postoperative device infection requiring explantation developed in 1 patient (1.8%). Intraoperative cultures from the pump site grew coagulase negative staphylococcus.
Conclusions:
Our data suggest that an antibiotic coated inflatable penile prosthesis may lead to decreased infection rates in patients undergoing penile prosthesis replacement for mechanical failure.
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin create...
Bacterial Signaling
Endocarditis IV: Nursing Management
Mechanism of Antibiotic Resistance in MRSA
Endocarditis III: Medical Management

