Related Experiment Video
Updated: Jul 19, 2026

GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
Determination of amantadine sulfate in sodium chloride injection by capillary gas chromatography
Weifeng Yao1, Xuefang Luo, Yuzhu Hu
1Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 210009, China.
Abstract:
This paper describes a new method to determine amantadine sulfate in sodium chloride injection by capillary gas chromatography. The chromatographic conditions of the methods employed a SGE BP-1 capillary column (30 m x 0.53 mm i.d., 1.0-microm film thickness); isothermal elution with N2 at a pressure of 100 KPa; injector, oven, and detector temperatures at 220 degrees C, 110 degrees C, and 220 degrees C, respectively; a split-less mode; and a 1-microL injection volume. Naphthalene was used as the internal standard. Peak purity testing with a Varian Saturn 2200 capillary gas chromatography- mass spectrometry system (Varian, Inc.) equipped with a DB-5 capillary column (30 m x 0.25 mm i.d., 0.25-microm film thickness) was performed for the investigation of specificity. There was a linear relationship between peak area ratios of analyte to the internal standard and concentration of analyte over the concentration range 0.1-2.0 mg/mL. The recovery was 97.8 approximately 100.7%. The relative standard deviation (%) of intermediate precision was less than 0.8. The limits of detection and quantitation were 0.2 microg/mL with a signal-to-noise ratio of 3, and 0.7 microg/mL with a signal-to-noise ratio of 10, respectively. The results of determination were similar to the titration method.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Qualitative Analysis
For instance, group IV...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...