Investigation of appropriate sanitization frequency for rodent caging accessories: evidence supporting less-frequent
Curtis W Schondelmeyer1, Dirck L Dillehay, Sonji K Webb
1Division of Animal Resources, Whitehead Biomedical Research Building, Emory University School of Medicine, Atlanta, Georgia, USA. schondelmeyer1@yahoo.com
Abstract:
The Guide for the Care and Use of Laboratory Animals states that sanitization of caging accessories (for example, filter tops and wire-bar lids) should be done every 2 wk. In this study we tested the hypothesis that organic contamination measured by the presence of ATP associated with organic material (measured with luciferase test swabs) and the number of bacterial colony-forming units (as determined by use of replicate organism detection and counting plates) on caging accessories did not differ significantly at 2 wk versus several months of use. The study evaluated 4 groups: mouse and rat ventilated and static wire-bar cages with or without filter tops (n = 10 per group). The cages were evaluated at several time points from 2 wk to 6 mo. For every cage type, ATP levels did not differ significantly between 14 and 90 d and, in most cases, between 14 and 180 d. In addition the number of bacterial colonies did not differ significantly between 14 and 120 d (and, in some cases, between 14 and 180 d). This study provides data relevant to establishing a validated frequency for sanitization of rodent caging accessories while controlling, and potentially decreasing, costs associated with sanitization.