Related Experiment Video
Updated: Jul 19, 2026

06:26
Quantitative Assessment Protocol for Facial Soft Tissue Volumetric Changes with Stereophotogrammetry
Published on: December 9, 2025
Facial motor function monitored by hand held calipers versus computer-assisted photography
L Clapham1, S Bottoms, R Mehta
1Department of Physiotherapy, Wessex Neurological Centre, Southampton, UK. Lorraine.Clapham@suht.swest.nhs.uk
Acta Neurochirurgica
|November 9, 2006
Summary
Computerised analysis of digital photographs (CAOP) is a reliable tool for assessing facial function, unlike hand-held calipers (HHC). CAOP offers objective measurements suitable for clinical use.
Area of Science:
- Medical imaging and analysis
- Biomechanical assessment of facial function
Background:
- Reliable tools are needed for assessing and comparing facial function in clinical settings.
- Two techniques, hand-held calipers (HHC) and computerised analysis of digital photographs (CAOP), were evaluated.
- The study aimed to compare the reliability and interchangeability of HHC and CAOP.
Purpose of the Study:
- To determine the agreement between two operators using HHC for facial landmark measurements.
- To determine the agreement between two operators using CAOP for facial landmark measurements.
- To explore if HHC and CAOP can be used interchangeably for assessing facial function.
Main Methods:
- Measurements of facial landmarks were taken at rest and during four facial expressions.
- Measurements were repeated after one week to assess inter/intra-rater reliability.
- Nine female volunteers with normal facial function participated.
Main Results:
- Computerised analysis of digital photographs (CAOP) demonstrated high intra- and inter-rater agreement.
- Hand-held calipers (HHC) showed low intra- and inter-rater agreement.
- CAOP proved to be a reliable method for objective measurement.
Conclusions:
- Hand-held calipers (HHC) are unreliable for monitoring facial function.
- Digital photography with Adobe Photoshop 7 offers a reliable, objective measurement tool.
- CAOP is simple, low-cost, and suitable for clinical application.