Related Experiment Video
Updated: Jul 19, 2026

An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Sensitive headspace gas chromatography-mass spectrometry determination of trihalomethanes in urine
1Department of Analytical Chemistry, Campus of Rabanales, University of Córdoba, E-14071 Córdoba, Spain.
Abstract:
A sensitive and straightforward method for the determination of trihalomethanes (THMs) in urine by using headspace extraction technique has been developed. Chemical and instrumental variables were studied in order to optimize the method for sensitivity: an excess of KCl (4 g per 12 ml of urine), an oven temperature of 85 degrees C and an equilibration time of 30 min were selected. The use of the mass spectrometer in selected ion monitoring mode allows achieving linear ranges between 10 and 5000 ng/l and detection limits from 3 to 10 ng/l, for 12 ml of urine. The stability of the urine sample during storage at 4 and -20 degrees C was also evaluated: THMs remained stable for up to 2 days and 2 months, respectively. Finally, the method was successfully applied to study the THM uptake from swimmers of an indoor swimming pool, as well as non-swimmers. This study revealed that the concentrations of THMs in urine increased approximately three times for chloroform and bromodichloromethane after swimming activity. In addition, THMs in unchanged form were mainly excreted within 2-3h after the end of exposure.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...