Related Experiment Video
Updated: Jul 18, 2026

Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
Prospective evaluation of double RBC collection using three different apheresis systems
Susanne M Picker1, Stela M Radojska, Birgit S Gathof
1Transfusion Medicine, University of Cologne, Kerpenerstr. 62, 50937 Cologne, Germany. susanne.picker@uk-koeln.de
Background:
Automated component collection systems offer the possibility of increasing blood supply and improving transfusion safety.
Design:
30 blood donors were randomly assigned to double RBC collection with either the Baxter Alyx (AX), the Haemonetics MCS Plus (MCS+), or the Gambro Trima Accel (TA). Procedures were prospectively evaluated focussing on yield, time, efficiency, citrate donor load, and in vitro quality.
Results:
All units showed sufficient in vitro quality throughout 42 days of storage and complied with international requirements. Donor reactions were limited to mild citrate reactions. AX was the fastest and most efficient system* * (* *p approximately 0.001) attaining the highest yield* * from similar amounts of whole blood. The drawbacks were a higher RBC loss* (*p < 0.05) and accelerated citrate infusion* *. Due to lower collection rates* * * (* * *p < 0.001), MCS+ was slower than TA* * * but compensated with lower citrate load * * *.
Conclusion:
Double RBC apheresis was performed safely and efficiently with all three instruments. AX had advantages for most parameters evaluated.

