Related Experiment Video
Updated: Jul 18, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients
Jochen Hinkelbein1, Harald V Genzwuerker, Reiner Sogl
1University Clinic for Anesthesiology and Intensive Care Medicine, Faculty of Clinical Medicine Mannheim, Ruprecht-Karls-University Heidelberg, University Hospital Mannheim, Mannheim, Germany. jochen.hinkelbein@anaes.ma.uni-heidelberg.de
Introduction:
Nail polish of different colours may alter accuracy and precision of pulse oximetry as previous data in healthy volunteers suggest. This trial evaluates the oxygen saturation determined by pulse oximetry and haematoximetry with nail polish of nine different colours applied.
Material And Methods:
Fifty critically ill and mechanically ventilated patients in an ICU were investigated in a prospective clinical-experimental trial. On nine finger nails polish of different colours was applied in a predetermined consecutive order. Functional oxygen saturation was determined by pulse oximetry (SpO2) on each finger for each colour with the finger sensor probe both in the normal position and at a 90 degrees rotation. Simultaneously oxygen saturation was determined by haematoximetry (SaO2). Accuracy (bias, DeltaS = SaO2-SpO2) and precision (standard deviation, S.D.) of pulse oximetry were analyzed with the t-test. A value of P < 0.05 was considered significant.
Results:
While black (DeltaS = +1.6+/-3.0%), purple (DeltaS = +1.2+/-2.6%) and dark blue nail polish (DeltaS = +1.1+/-3.5%, each N = 50) had the greatest effect (P < 0.05), all other colours, including colourless nail polish, had a smaller effect (mean bias +0.2 to +0.9%). A rotation of 90 degrees reduced the bias from +2.8 to +1.3% (N = 10, n.s.).
Conclusion:
Nail polish does not alter pulse oximetry readings in mechanically ventilated patients to a clinically relevant extent. The mean error of measurement for all colours was within the manufacturers' specified range of +/-2%. A 90 degrees rotation of the sensor probe does not eliminate errors in measurement. To remove nail polish might be helpful to decrease the error of measurement in some cases.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Transport in the Blood