Related Experiment Video
Updated: Jul 18, 2026

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
New technique of direct intra-abdominal pressure measurement
Elena Risin1, Boris Kessel, Noah Lieberman
1Department of Anesthesiology and Trauma Unit, Hillel Yaffe Medical Center, Hadera, Israel. trauma@hillel-yaffe.health.gov.il
Objective:
To determine the efficacy of 14-Fr PVC round drain in the direct measurement of intra-abdominal pressure.
Methods:
Fifty consecutive patients undergoing elective laparoscopic surgery in a tertiary teaching hospital were included in this pilot study. Patients underwent laparoscopic cholecystectomy, appendectomy, splenectomy, colectomy and Nissen fundoplication. After creation of pneumoperitoneum and insertion of the trocars as indicated by the operation, a 14-Fr PVC round drain was inserted into the abdominal cavity via one of the laparoscopic ports. It was then connected under sterile conditions to the invasive blood pressure measurement system. Intra-abdominal pressure was gradually increased. Intra-abdominal pressures as measured through the round PVC drain were compared to those measured by the laparoscopic insufflator at 5, 8, 12 and 24 mmHg.
Results:
Two hundred measurements using each of the two methods were performed and correlated. The correlation coefficient was 0.996. No complications were observed with this new technique.
Conclusion:
Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Abdomen III: Palpation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
