Related Experiment Video
Updated: Jul 18, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Performance of monolithic silica capillary columns with increased phase ratios and small-sized domains
Takeshi Hara1, Hiroshi Kobayashi, Tohru Ikegami
1Department of Polymer Science and Engineering, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto, 606-8585, Japan.
Abstract:
Monolithic silica capillary columns for HPLC were prepared from tetramethoxysilane to have smaller sized domains and increased phase ratios as compared to previous materials, and their performance was evaluated. The monolithic silica columns possessed an external porosity of 0.65-0.76 and a total porosity of 0.92-0.95 and showed considerably higher performance and greater retention factors in a reversed-phase mode after chemical modification than columns previously reported. An octadecylsilylated monolithic silica column with the smallest domain size (through-pores of approximately 1.3 microm and silica skeletons of approximately 0.9 microm) showed a plate height of less than 5 microm at optimum linear velocities (u) of 2-3 mm/s in 80% acetonitrile for a solute having retention factors of approximately 1, and approximately 7 microm at u = 8 mm/s. With a permeability similar to that of a column packed with 5-microm particles, the monolithic silica columns were able to attain column efficiencies comparable to that of particulate columns packed with 2-2.5-microm particles, and showed performance in the "forbidden region" for the previous columns. The performance of the monolithic column can be compared favorably with that of a particle-packed column when 15,000-30,000 or more theoretical plates are desired at a pressure drop of 20-40 MPa or lower. The increased homogeneity of the co-continuous structures, in addition to the small-sized domains, contributed to the higher performance as compared to previous monolithic silica columns.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process