Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia
Raffaele Corbisiero1, Michael A Lee, David R Nabert
1Deborah Heart and Lung Center, 200 Trenton Road, Browns Mills, NJ 08018, USA. corbisieror@deborah.org
Aims:
Interval- and morphology-based algorithms have been used in modern implantable cardioverter defibrillators (ICDs) to discriminate supraventricular tachycardia (SVT) from other rhythms. A newly developed ICD discrimination algorithm, Rhythm ID (Guidant Corporation, St Paul, MN, USA), uses both interval-based metrics and an electrogram vector timing and correlation (VTC) algorithm in a dual-chamber ICD. In a single-chamber ICD, Rhythm ID contains only the VTC component. This study conducted a retrospective analysis of the performance of Rhythm ID for the detection of induced and spontaneous rhythms in a single-chamber ICD.
Methods And Results:
This study gathered the data from a prospective, multicentre clinical trial. Ninety-six patients were implanted with a dual-chamber ICD. For this study, each episode was analysed to determine the performance of the single-chamber ICD Rhythm ID algorithm. The mean age of the patients implanted with the device was 67+/-11 years. Seventy-eight patients were male. The primary cardiovascular disease was coronary artery disease and the primary tachyarrhythmia was monomorphic ventricular tachycardia (VT). The mean follow-up time was 11.4 months. A total of 369 induced and spontaneous ventricular arrhythmias was analysed. The algorithm detected 100% of ventricular arrhythmias. Four hundred and forty-two SVT episodes were analysed, including 145 induced and 297 spontaneous. The SVTs were atrial fibrillation (n=199), atrial flutter (n=135), and 1:1 SVT (n=108). The single-chamber ICD Rhythm ID algorithm successfully discriminated 403 SVT episodes and achieved a specificity of 91%.
Conclusion:
The single-chamber version of Rhythm ID demonstrated high specificity without compromising sensitivity.
Related Concept Videos
Dysrhythmias II: Classification of Tachyarrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...