Related Concept Videos

Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Colloidal precipitates01:09

Colloidal precipitates

The high insolubility of some precipitates can result in an unfavorable relative supersaturation. This can lead to colloidal particles with a large surface-to-mass ratio, where adsorption is promoted. For instance, in the precipitation of silver chloride, silver ions are adsorbed on the surface of the colloidal particles, forming a primary layer. This layer attracts ions of opposite charge (such as nitrate ions), forming a diffuse secondary layer of adsorbed ions. This electric double layer...
Washing, Drying, and Ignition of Precipitates00:52

Washing, Drying, and Ignition of Precipitates

After filtration, the precipitate is washed to remove coprecipitated impurities and any remaining mother liquor. Colloidal precipitates, such as silver chloride, are washed with an electrolyte (such as dilute nitric acid) to prevent the peptization of the precipitate. In the case of slightly soluble precipitates, the wash solution contains a common ion to reduce solubility. Lead sulfate, which is slightly soluble in water, is washed with dilute sulfuric acid. Similarly, wash solutions may be...
Preparation of Samples for Electron Microscopy01:20

Preparation of Samples for Electron Microscopy

To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
Precipitation and Co-precipitation01:17

Precipitation and Co-precipitation

Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
Precipitation Gravimetry01:03

Precipitation Gravimetry

Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A highly conserved basic motif in the wing domain of portal protein is necessary for oligomerization and incorporation in phage P22.

Journal of virology·2026
Same author

Optimization of Radially Segmented Ion Mirrors for High Resolution Charge Detection Mass Spectrometry.

Journal of the American Society for Mass Spectrometry·2026
Same author

Polyanionic Sugars Drastically Affect Assembly of Human Papilloma Virus Virus-Like Particles.

ACS infectious diseases·2025
Same author

End-to-end characterization of AAV manufacturing process using charge detection mass spectrometry.

Molecular therapy. Methods & clinical development·2025
Same author

Erratum: End-to-end characterization of AAV manufacturing process using charge detection mass spectrometry.

Molecular therapy. Methods & clinical development·2025
Same author

Coupling Drift Tube Ion Mobility Measurements with Charge Detection Mass Spectrometry for the Analysis of Virus-like Particles and Other Megadalton-Sized Ions.

Analytical chemistry·2025

Related Experiment Video

Updated: Jul 18, 2026

Glass-Based Devices to Generate Drops and Emulsions
08:45

Glass-Based Devices to Generate Drops and Emulsions

Published on: April 5, 2022

Negative droplets from positive electrospray.

Joshua T Maze1, Thaddeus C Jones, Martin F Jarrold

  • 1Chemistry Department, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, USA.

The Journal of Physical Chemistry. A
|November 17, 2006
PubMed
Summary

Electrosprayed water droplets were measured for charge and velocity. Surprisingly, a small fraction of positively biased electrosprayed droplets were negatively charged, possibly due to bipolar fission.

More Related Videos

Additive Manufacturing-Enabled Low-Cost Particle Detector
06:05

Additive Manufacturing-Enabled Low-Cost Particle Detector

Published on: March 24, 2023

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
07:57

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics

Published on: November 10, 2014

Related Experiment Videos

Last Updated: Jul 18, 2026

Glass-Based Devices to Generate Drops and Emulsions
08:45

Glass-Based Devices to Generate Drops and Emulsions

Published on: April 5, 2022

Additive Manufacturing-Enabled Low-Cost Particle Detector
06:05

Additive Manufacturing-Enabled Low-Cost Particle Detector

Published on: March 24, 2023

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
07:57

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics

Published on: November 10, 2014

Area of Science:

  • Physics
  • Chemistry

Background:

  • Electrospraying is a technique used to generate charged droplets.
  • Understanding droplet charge is crucial for controlling applications.

Purpose of the Study:

  • To investigate the charge distribution of electrosprayed water droplets.
  • To explore the reasons behind the unexpected observation of negatively charged droplets.

Main Methods:

  • Utilized image charge detection to measure individual droplet charge and velocity.
  • Applied a positive bias to the electrospray needle.

Main Results:

  • The majority of electrosprayed water droplets were positively charged, as expected.
  • A small but significant fraction of droplets unexpectedly exhibited negative charges.

Conclusions:

  • The presence of negatively charged droplets challenges conventional expectations.
  • Bipolar fission is proposed as a plausible mechanism, where a small negative droplet forms between two larger positive droplets, facilitating fission.