Receiver operating characteristic curve inference from a sample with a limit of detection
Neil J Perkins1, Enrique F Schisterman, Albert Vexler
1Division of Epidemiology, Statistics, and Prevention Research, National Institute of Child Health and Human Development, National Institutes of Health, Department of Health and Human Services, Bethesda, MD, USA.
Abstract:
The receiver operating characteristic curve is a commonly used tool for evaluating biomarker usefulness in clinical diagnosis of disease. Frequently, biomarkers being assessed have immeasurable or unreportable samples below some limit of detection. Ignoring observations below the limit of detection leads to negatively biased estimates of the area under the curve. Several correction methods are suggested in the areas of mean estimation and testing but nothing regarding the receiver operating characteristic curve or its summary measures. In this paper, the authors show that replacement values below the limit of detection, including those suggested, result in the same biased area under the curve when properly accounted for, but they also provide guidance on the usefulness of these values in limited situations. The authors demonstrate maximum likelihood techniques leading to asymptotically unbiased estimators of the area under the curve for both normally and gamma distributed biomarker levels. Confidence intervals are proposed, the coverage probability of which is scrutinized by simulation study. An example using polychlorinated biphenyl levels to classify women with and without endometriosis illustrates the potential benefits of these methods.
Related Concept Videos
Receiver Operating Characteristic Plot
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2. The spectrum...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...