Related Experiment Video
Updated: Jul 18, 2026

Sample Preparation for Computed Tomography-based Three-dimensional Visualization of Murine Hind-limb Vessels
Published on: October 7, 2021
A comparison of primary two- and three-dimensional methods to review CT colonography
Rogier E van Gelder1, Jasper Florie, C Yung Nio
1Department of Radiology, Academic Medical Center of the University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands. r.e.vangelder@amc.uva.nl
Abstract:
The aim of our study was to compare primary three-dimensional (3D) and primary two-dimensional (2D) review methods for CT colonography with regard to polyp detection and perceptive errors. CT colonography studies of 77 patients were read twice by three reviewers, first with a primary 3D method and then with a primary 2D method. Mean numbers of true and false positives, patient sensitivity and specificity and perceptive errors were calculated with colonoscopy as a reference standard. A perceptive error was made if a polyp was not detected by all reviewers. Mean sensitivity for large (> or = 10 mm) polyps for primary 3D and 2D review was 81% (14.7/18) and 70%(12.7/18), respectively (p-values > or = 0.25). Mean numbers of large false positives for primary 3D and 2D were 8.3 and 5.3, respectively. With primary 3D and 2D review 1 and 6 perceptive errors, respectively, were made in 18 large polyps (p = 0.06). For medium-sized (6-9 mm) polyps these values were for primary 3D and 2D, respectively: mean sensitivity: 67%(11.3/17) and 61%(10.3/17; p-values > or = 0.45), number of false positives: 33.3 and 15.6, and perceptive errors : 4 and 6 (p = 0.53). No significant differences were found in the detection of large and medium-sized polyps between primary 3D and 2D review.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VI: Voiding Cystourethrography and Cystography