Tendinopathy and Doppler activity: the vascular response of the Achilles tendon to exercise
M I Boesen1, M J Koenig, S Torp-Pedersen
1The Parker Institute, Frederiksberg Hospital, Frederiksberg, Copenhagen, Denmark. parker@fh.hosp.dk
Background:
Intratendinous Doppler activity has been interpreted as an equivalent of neovessels in the Achilles tendon and as a sign of tendinosis (AT).
Aim:
To evaluate the vascular response as indicated by color Doppler activity after repeated loading of both symptomatic and non-symptomatic Achilles tendons.
Material And Methods:
Ten non-trained, healthy subjects ran 5 km. Ultrasound (US) Doppler activity was determined before and after the exercise. Eleven patients with chronic AT performed 3 x 15 heavy-load eccentric exercise. The Achilles tendons were scanned before and immediately after the exercise.
Results:
Non-symptomatic: six Achilles tendons in five subjects had intratendinous Doppler activity before the exercise. All but two subjects (80%) had intratendinous Doppler activity after running. Symptomatic: all patients had Doppler activity in the tendons, with a median color fraction before eccentric exercise of 0.05 (range 0.01-0.33). The Doppler activity did not disappear after exercise. Tendons with a color fraction below the median at baseline increased significantly after the exercise (P=0.02).
Conclusion:
The mere presence of Doppler in the Achilles tendon does not per se indicate disease. Eccentric exercise does not extinguish the flow during or after one training session in patients with chronic AT.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse Assessment Sites
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection