Related Experiment Video
Updated: Jul 18, 2026

Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile
Published on: September 20, 2024
Predictions of postoperative visual outcome in subjects with cataract: a preoperative and postoperative study
William A Douthwaite1, Marta Vianya-Estopà, David B Elliott
1Department of Optometry, University of Bradford, Bradford, West Yorkshire BD7 1DP, UK. w.a.douthwaite@bradford.ac.uk
Aim:
To assess the ability of critical flicker frequency (CFF) and optimal reading speed (ORS) to predict the potential vision in patients with cataract with and without ocular comorbidity.
Methods:
The two novel tests were compared with two well established potential vision tests (PVTs), the potential acuity meter (PAM) and the laser interferometer (LI). Measurements were made preoperatively in 1 eye of 88 subjects using the battery of 4 PVTs. Postoperative measurements were made with the CFF and the ORS. The subjects studied were consecutive cases over a 12-month period who fulfilled the inclusion and exclusion criteria, and agreed to participate in this study.
Results:
CFF was the PVT most resistant to the presence of cataract. Both CFF and ORS give a similar predictive precision in the presence of cataract and ocular comorbidity, although CFF seems more precise when the cataract is dense.
Conclusions:
The PAM and the LI showed a limited clinical capability in predicting postoperative visual acuity, particularly with dense opacities. The CFF shows the most promise as a PVT, particularly with dense cataract. Further evaluation is required for both CFF and ORS.