R Arora1, D Fritz, R Zimmermann
1Department of Trauma Surgery and Sports Medicine, Medical University Innsbruck (MUI), Innsbruck, Austria. rohit.arora@uibk.ac.at
Abstract:
The rare injury of closed rupture of the A2 and A3 flexor pulleys was treated using two non-encircling techniques of pulley reconstruction. Thirteen patients were treated with an extensor retinaculum graft (Group A). At a mean follow-up time of 48 months, the average PIP flexion was 97%, the power grip strength 96%, the pinch grip strength 100% and the thickening 94% of the uninjured side. Ten patients were treated with a free palmaris longus tendon grafts (Group B). At a mean follow-up time of 57 months, the average PIP flexion was 94%, the power grip strength 98%, the pinch grip strength 100% and the thickening 95% of the uninjured side. In both groups, finger extension was unrestricted. The Buck Gramcko score included 10 excellent, two good and one fair result in Group A and seven excellent, two good and one fair result in Group B. Both techniques proved beneficial. All climbers returned to their previous standard and all non-climbers regained full finger dexterity in their previous job.