Simultaneous Electrical and Mechanical Stimulation to Enhance Cells' Cardiomyogenic Potential
Published on: January 18, 2019
Effects of synchronized cardiac assist device on cardiac energetics
Amir Landesberg1, Avshalom Shenhav, Rona Shofty
1Department of Biomedical Engineering, Technion, Israel Institute of Technology, Haifa 32000 Israel. amir@bm.technion.ac.il
Abstract:
A novel physiological cardiac assist device (PCAD), the LEV RAM assist device, which is synchronized with the failing heart ejection, was developed to improve the failing heart systolic and diastolic functions and cardiac energetics. The PCAD uses a single short cannula, which is inserted into the beating left ventricle (LV) by means of a specially designed device. Blood is ejected from the PCAD into the LV after the opening of the aortic valve and augments the cardiac stroke work. The same amount of blood is withdrawn from the LV into the PCAD, through the same cannula, during the diastole. The study aims to test the effects of the PCAD on cardiac energetics and coronary blood flow. Adult normal sheep were anesthetized and the heart was exposed by left thoracotomy. Pressures transducers (Millar Instruments, Inc., Houston, TX) were inserted into the LV and aorta. LV volume was measured by sonocrystals (Sonometrics Corp., London, Ontario, Canada) and impedance catheter (CD Lycom, Argonstrat 116 Zoetermeer, 2718 SP The Netherlands). Flowmeters (transonic) measured the cardiac output (CO) and the coronary arteries (left anterior descending (LAD) and circumflex) flows. A thin cannula was inserted into the coronary sinus and the oxygen content of the LV and the coronary sinus were determined (AVOXimeter-1000). Pressure-volume loops, myocardial energetics, and coronary flow were measured. The displaced PCAD volume was 11 mL. Four different levels of assist were studied by changing the frequency of the assist: (1) assist beat after three successive regular beats [1:4], (2) assist every third beat [1:3], (3) alternate assist and normal beat [1:2], and (4) continuous assist [1:1]. Cardiac output (CO) and stroke volume (SV) increased proportionally with increasing frequency of assist. Systolic mechanical efficiency of the PCAD was above 90%. Simultaneously, the PCAD decreased the end-diastolic volume (EDV; diastolic unloading). The PCAD increased coronary flow and decreased cardiac arterial-venous O(2) difference. We conclude that the PCAD efficiently augments CO and stroke work, decreases preload, and decreases the coronary arterial-venous O(2) difference; all these may expedite cardiac reverse remodeling, and promote recovery of function and eventual easy explanation of the device.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Related Concept Videos
Pathophysiology of Cardiac Performance
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Heart Failure Drugs: Inotropic Agents
Cardiomyopathy II: Dilated Cardiomyopathy
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...