Related Experiment Video
Updated: Jul 18, 2026

Fabrication of Compressed Hosiery and Measurement of its Pressure Characteristic Exerted on the Lower Limbs
Published on: May 27, 2020
A novel technique to determine pressure in pressure garments for hypertrophic burn scars and comfort properties
1Department of Textile Engineering, Pamukkale University, Denizli, Turkey. niluferyildizny@yahoo.com
Abstract:
Current recommendations state that pressure garments should be worn for up to 2 years for hypertrophic burn scars. Thermo-physiological properties of pressure garments were assessed by the thermo-physiological tests and a comparison of the fabric with a sportwool which is a single-jersey knitted fabric was performed. In this novel technique, it was aimed to determine the exact pressure of pressure garments on the applied body part. For the theoretical part of this study, the Laplace equation was used with an optimum pressure of 20 mmHg and a relationship between change in length versus circumference was calculated. To determine the change in length a ruler was prepared for each predetermined circumference value using this relationship. Grid printed fabric samples were prepared with an interval of 2 cm in width direction to be used for the calculation of mean pressure on a Mannequin Leg. The resultant mean pressure calculated experimentally on Mannequin Leg as 24 mmHg was compared to the optimum pressure of 20 mmHg. It was observed that the two values were not statistically significantly different.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Assessment of blood pressure in brachial artery(two-step method)

