Related Experiment Video
Updated: Jul 18, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Quantification of dichloroiodomethane and bromochloroiodomethane in human blood by solid-phase microextraction
Lalith K Silva1, Michael A Bonin, Bruce McKague
1Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, Georgia 30341, USA. LSILVA@cdc.gov
Abstract:
Iodine-containing trihalomethanes (iodo-THMs) are formed as disinfection byproducts when iodide-containing water is disinfected using chloramination process. Subsequent water use may lead to human exposure to iodo-THMs. Because of health concerns surrounding exposure to iodo-THMs, a rapid, reliable, and high-throughput analytical method was developed to quantify trace levels of two iodo-THMs: dichloroiodomethane (IDCM) and bromochloroiodomethane (IBCM) in human blood. These analytes from the headspace above blood samples were extracted using solid-phase microextraction. Analytes were then desorbed and separated by capillary gas chromatography and analyzed by high-resolution mass spectrometry with multiple ion monitoring. This method utilizes stable isotope dilution to quantify parts-per-trillion levels of all analytes, with excellent precision of < 9% coefficient of variation. At three spiked levels, method accuracy of IDCM and IBCM ranged between 6 and 20% difference when comparing spiked and measured amounts. The method limit of detection was 2 ng/L for both IDCM and IBCM. This selective, sensitive, and rapid method will help to assess human exposure to iodo-THMs and to study potential associations between exposure and adverse health outcomes.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
12:59A Study of the Complexation of Mercury(II) with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
Related Concept Videos
Mass Spectrometry: Alkyl Halide Fragmentation
Chemical Ionization (CI) Mass Spectrometry
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...