Related Experiment Video
Updated: Jul 18, 2026

Using the Endoscope for Endobronchial Ultrasound in the Esophagus
Published on: November 21, 2023
Unsedated ultrathin EGD by using a 5.2-mm-diameter videoscope: evaluation of acceptability and diagnostic accuracy
Akira Horiuchi1, Yoshiko Nakayama
1Department of Gastroenterology, Showa Inan General Hospital, Komagane, Japan.
Background:
This study was designed to assess the acceptability and the diagnostic accuracy of unsedated ultrathin EGD (uUT-EGD) by using a newly developed 5.2-mm-diameter videoscope compared with unsedated small-caliber EGD (uSC-EGD) by using a 6.5-mm-diameter videoscope or sedated conventional EGD (sC-EGD) by using a 9.0-mm-diameter videoscope.
Design:
First, 80 patients who had undergone uSC-EGD approximately 1 year earlier were randomized to receive uUT-EGD (n = 40) or uSC-EGD (n = 40). Endoscopist satisfaction and patient comfort were assessed by using a 10-cm visual analog scale. Patient comfort level was compared with that of the previous uSC-EGD. Second, 40 patients who had undergone sC-EGD within the previous 1.5 years underwent uUT-EGD. The optical quality and EGD findings of uUT-EGD were compared with those of the previous sC-EGD. Last, in the 80 patients undergoing uUT-EGD, the ability to identify a validated endoscopic marker, the rearrangement of collecting venues (RAC) pattern, for no Helicobacter pylori, was compared with the results of a (13)C-urea breath test or H pylori stool antigen test.
Setting:
Showa Inan General Hospital, Komagane, Japan.
Patients:
A total of 120 patients who undergo EGD every year as part of a gastric cancer surveillance program.
Results:
The patient comfort level of uUT-EGD was significantly better than that of uSC-EGD (P < .0001). The optical quality of the endoscopic images and the EGD findings of uUT-EGD were similar to those of the previous sC-EGD. The overall sensitivity, specificity, and accuracy of the RAC pattern in uUT-EGD in recognizing H pylori-uninfected patients were 90%, 100%, and 93%, respectively. The interobserver agreement for RAC was good (kappa = 0.42).
Conclusions:
The use of a 5.2-mm-diameter videoscope is expected to enhance the patient acceptance of unsedated EGD.
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures III: Video Capsule Endoscopy
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):