Related Experiment Video
Updated: Jul 18, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Removal of two waterborne pathogenic bacterial strains by activated carbon particles prior to and after charge
Henk J Busscher1, Rene J B Dijkstra, Eefje Engels
1Department of Biomedical Engineering, University Medical Center Groningen and University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands.
Abstract:
Waterborne diseases constitute a threat to public health despite costly treatment measures aimed at removing pathogenic microorganisms from potable water supplies. This paper compared the removal of Raoultella terrigena ATCC 33257 and Escherichia coli ATCC 25922 by negatively and positively charged types of activated carbon particles. Both strains display bimodal negative zeta-potential distributions in stabilized water. Carbon particles were suspended to an equivalent external geometric surface area of 700 cm2 in 250 mL of a bacterial suspension, with shaking. Samples were taken after different durations for plate counting. Initial removal rates were less elevated for the positively charged carbon particle than expected, yielding the conclusion that bacterial adhesion under shaking is mass-transport limited. After 360 min, however, the log-reduction of the more negatively charged R. terrigena in suspension was largest for the positively charged carbon particles as compared with the negatively charged ones, although conditioning in ultrapure or tap water of positively charged carbon particles for 21 days eliminated the favorable effect of the positive charge due to counterion adsorption from the water. Removal of the less negatively charged E. coli was less affected by aging of the (positively charged) carbon particles, confirming the role of electrostatic interactions in bacterial removal by activated carbon particles. The microporous, negatively charged coconut carbon performed less than the mesoporous, positively charged carbon particle prior to conditioning but did not suffer from loss of effect after conditioning in ultrapure or tap water.
More Related Videos
09:39Physical, Chemical and Biological Characterization of Six Biochars Produced for the Remediation of Contaminated Sites
Published on: November 28, 2014
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
Related Concept Videos
Coagulation
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Bioremediation
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...