Related Experiment Video
Updated: Jul 18, 2026

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Mid-term results of titanium hemi-great toe implants
Kurt Frederick Konkel1, Andrea Gayle Menger
1Advanced Healthcare, Inc., Orthopaedics, 484216889 Menomonee Avenue, Menomonee Falls, Wisconsin 53051, USA. kkonke@ah.com
Background:
We reviewed the mid-term results of metatarsophalangeal hemiarthroplasty with titanium hemi-great toe implants. This study may help with future prosthetic design and evaluation leading to improved management and patient satisfaction.
Methods:
Ten of 12 patients were contacted more than 2.5 years after surgery. Their charts were reviewed, and they were evaluated clinically and radiographically.
Results:
All patients were improved and satisfied in the first 5 years after surgery, but subsidence and lucency in all patients and a painful fracture in one patient bring long-term implant survival into question. The ultimate longevity of the implant and its long-term functionality should be questioned.
Conclusions:
Metallic hemi-great toe implants have satisfactory mid-term results. Improved prosthetic design may lead to less implant subsidence and stem lucency.