Can the modified Allen's test always detect sufficient collateral flow in the hand? A computational study
J Alastruey1, K H Parker, J Peiró
1Department of Aeronautics, Imperial College London, South Kensington Campus, London SW7 2AZ, UK.
The modified Allen's test (MAT) can inaccurately assess collateral blood flow due to small artery size or incomplete compression. Digital pressure measurements offer a more sensitive alternative for evaluating hand blood supply.
Area of Science:
- Biomedical Engineering
- Cardiovascular Physiology
- Medical Imaging and Modeling
Background:
- Assessing collateral circulation in the hand is crucial for preventing ischemia after radial artery procedures.
- The modified Allen's test (MAT) is commonly used but its accuracy can be compromised.
- Numerical modeling provides a powerful tool to investigate the hemodynamics of arterial networks.
Purpose of the Study:
- To numerically model blood flow in arm arteries to evaluate the modified Allen's test (MAT).
- To assess the suitability of MAT for detecting sufficient collateral hand circulation when radial artery supply is interrupted.
- To identify factors influencing the accuracy of MAT and digital pressure measurements.
Main Methods:
- One-dimensional numerical modeling of pressure and flow wave propagation in compliant arterial vessels.
- Simulation of arterial compression to replicate the modified Allen's test (MAT) conditions.
- Analysis of blood flow in the superficial palmar arch and digital systolic pressures during simulated radial artery compression.
Main Results:
- Small superficial palmar arch calibres and insufficient radial artery compression can lead to false-positive MAT results.
- Measurement of digital systolic pressure drop during radial artery compression is more sensitive for detecting ulnar collateral flow in small-calibre vessels.
- Digital pressure measurements can also be unreliable with insufficient radial artery compression.
Conclusions:
- The study highlights limitations of the modified Allen's test (MAT), particularly in cases of small superficial palmar arches.
- Digital systolic pressure measurement is a more sensitive indicator of collateral hand blood flow than MAT.
- Optimized compression techniques are necessary for both MAT and digital pressure measurements to ensure accurate assessment of collateral circulation.