[Evaluation of different breathing and contrast-protocols concerning quality and alignment in 18F-FDG PET/CT]
M N Vogel1, K Brechtel, M D Klein
1Diagnostische Radiologie, Eberhard-Karls-Universität Tübingen. monika.vogel@med.uni-tuebingen.de
Purpose:
The purpose of this study was to establish a reliable and simple parameter for alignment evaluation and the evaluation and optimization of state-of-the-art contrast-enhanced examination protocols for (18)F FDG-PET/CT.
Materials And Methods:
44 consecutive patients were referred to 4 examination protocols. Group A and B underwent single-phase, contrast-enhanced CT (90 s delay) performed either during free shallow breathing (FA; group A) or normal expiration (NormExp; group B). Groups C and D underwent arterial and portal venous multiphase examinations performed during FA (group C) or during NormExp (group D) followed by a low-dose CT scan for attenuation correction. Organ displacement in the cranio-caudal direction was correlated with a 3D-vectorial shift. For alignment evaluation discrepancies with respect to size and liver location, the spleen and kidneys were calculated. Additionally, the groups were compared with regard to the presence of CT artifacts.
Results:
Cranio-caudal organ shift and 3D-vectorial shift showed a high correlation (r > 0.8). Single-phase CT scans performed during NormExp yielded better image quality (p < 0.001) and alignment (p < 0.01 for liver, spleen and right kidney) than those performed during FA. Differences in organ size did not differ during FA and NormExp. Depending on the evaluated organ, breathing and contrast protocol misalignment was in the cranio-caudal direction 0-27 mm (mean: 6.8; standard deviation: +/- 4.9) in multiphase CT compared to 0 - 11 mm (mean: 4.5 +/- 2.3) in single-phase examinations.
Conclusion:
1. Organ shift in the cranio-caudal direction is a good and simple parameter for alignment evaluation. 2. Alignment and CT quality are best in expiration protocols. 3. Despite comparatively low alignment quality, integrated multiphase CT examinations show acceptable quality and alignment.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT