Monte Carlo simulations of occupational radiation doses in interventional radiology
T Siiskonen1, M Tapiovaara, A Kosunen
1STUK-Radiation and Nuclear Safety Authority, PO Box 14, FIN-00881 Helsinki, Finland. teemu.siiskonen@stuk.fi
Abstract:
Occupational radiation doses in interventional radiology can potentially be high. Therefore, reliable methods to assess the effective dose are needed. In the present work, the relationship between the personal dose equivalent, H(p)(10), the reading of a personal dosimeter and the effective dose of the radiologist were studied using Monte Carlo simulations. In particular, the protection provided by a lead apron was investigated. Emphasis was placed on sensitivity of the results to changes in irradiation conditions. In our simulations a 0.35 mm thick lead apron and thyroid shield reduced the effective dose, on average, by a factor of 27 (the range of these data was 15-41). Without the thyroid shield the average reduction factor was 15 (range 6-22). The reduction sensitively depended on the projection and the X-ray tube voltage. The dosimeter reading, when the dosimeter was worn above the apron and a thyroid shield was used, overestimated the effective dose on average by a factor of 130 (range 44-258) when the dosimeter was located on the breast closest to the primary X-ray beam. Without the thyroid shield the average overestimation was 69 (range 32-127). If the dosimeter was worn under the apron its reading generally underestimated the effective dose (on average by 20% with the thyroid shield). Our study indicates that, even though large variations are present, the often used conversion coefficient from the dosimeter reading above the apron to the effective dose, around 1/30, generally overestimates the effective dose by a factor of two or more.
Related Concept Videos
Radiation: Applications
The average...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...