Two-color medium-infrared scanning interferometer for the Frascati tokamak upgrade fusion test device
A Canton1, P Innocente, O Tudisco
1Consorzio RGX, Associazione Euratom/ENEA, Corsi Stati Uniti, Italy. alessandra.canton@igi.cnr.it
Abstract:
A scanning beam interferometer installed on the Frascati tokamak upgrade (FTU) experiment is presented. The scanning beam scheme combined with the small dimensions of the beams produces a system with very high spatial resolution: more than 30 adjacent (nonoverlapping) chords sample most of the plasma cross section. A good time resolution is achieved by the use of a proper scanning device, with a scanning frequency >or=8 kHz. Very fast events are measured by three additional fixed lines of sight providing a time resolution >or=100 kHz. The instrument is a two-color medium-infrared-compensated-type interferometer; two wavelengths (colors) are used to measure both the density and the mechanical vibrations of optical components. A CO2 laser (lambda=10.6 microm) is the main light source, and a CO laser (lambda=5.4 microm) is the compensation one. The optical scheme is a double pass Mach-Zehnder type. All the retroreflector mirrors are mounted directly on the FTU mechanical structure thanks to the compensation system that allows for large vibration amplitudes of optical components. Heterodyne detection at 30 and 40 MHz is obtained by frequency shifting the reference beams with two acousto-optic modulators (Bragg cells). Many features are implemented to achieve high measurement accuracy and reliability. A real-time system computes the integral density measured on one of the fixed lines of sight and provides an analog signal for density feedback control. The interferometer was used to measure density profiles both in medium-density discharges (n(e) approximately 10(20) m(-3)) and in high-density pellet injected discharges (n(e) approximately 7-8 x 10(20) m(-3)). The measurement error is approximately 2 x 10(18) m(-2) under optimal conditions but can be higher in some cases, mainly because of the large tilt of the retroreflector mirrors.
Related Concept Videos
IR Spectrometers
Tandem Mass Spectrometry
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.