Change-point detection of gaseous and particulate traffic-related pollutants at a roadside location
David C Carslaw1, Karl Ropkins, Margaret C Bell
1Institute for Transport Studies, University of Leeds, Leeds LS2 9JT, UK. d.c.carslaw@its.leeds.ac.uk
Abstract:
An 8-year (1998-2005), hourly data set of measurements of NOx, NO2, PM10, PM2.5, and PMcoarse (defined as PM(2.5-10)) from a busy roadside location in central London has been analyzed to identify important change-points in the time series using a cumulative sum (CUSUM) technique. Randomization methods were used to estimate the uncertainty level associated with the change-points with uncertainty intervals derived using a bootstrap approach. The results show that there is a clear change-point increase for NO2 coinciding with the introduction of the London congestion-charging in February 2003 (95% confidence interval from January-March 2003). At this time there was both an increase in bus numbers and buses fitted with catalyzed diesel particulate filters, which increase direct emissions of NO2. A highly statistically significant change-point was also observed for PMcoarse (95% confidence interval from December 2002-February 2003), which also occurred close to the time of the congestion charge introduction and is most closely related to the increase in bus flows. The increase in PMcoarse at this time has largely compensated for reductions in the concentration of PM2.5, such that the concentration of PM10 has remained almost constant. Comparing the 2 years before and after the introduction of congestion charging, the increment in NO2 above background increased from 22 to 34 ppb and PMcoarse increased from 4 to 9 microg m(-3). These results could have important implications for meeting European air quality standards that currently set limits for PMlo rather than PM2.5.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...