Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

3D contrast-enhanced MR angiography.

Honglei Zhang1, Jeffrey H Maki, Martin R Prince

  • 1Department of Radiology, Weill Medical College of Cornell University, New York, New York, USA.

Journal of Magnetic Resonance Imaging : JMRI
|December 13, 2006
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An in situ non-contact 3D microscopic measurement system for temporal bone anatomy based on stereo imaging.

Scientific reports·2026
Same author

Clinical characteristics of hospitalized patients with benign gallbladder disease: a large-scale retrospective analysis.

BMC gastroenterology·2026
Same author

A horizontal connectivity mode in coastal oceans: transport overrides stratification to govern microbiome network stability.

Applied and environmental microbiology·2026
Same author

CD20 re-emergence in a patient with diffuse large b-cell lymphoma who experienced a CD20-negative relapse after glofitamab treatment.

Haematologica·2026
Same author

Japanese encephalitis virus NS1 and NS4B synergistically target TLR3 signaling to promote viral replication.

mBio·2026
Same author

Coordination-Modulated MOF-Derived Electrocatalysts for Enhanced C─C Coupling in CO<sub>2</sub> to C<sub>2</sub>H<sub>4</sub> and C<sub>2</sub>H<sub>5</sub>OH Conversion.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same journal

Editorial for "Association Between Deep Gray Matter Iron Deposition Dysregulation and Cognitive Performance in Type 2 Diabetes Mellitus Patients: A Quantitative Susceptibility Mapping Study".

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Association Between Deep Gray Matter Iron Deposition Dysregulation and Cognitive Performance in Type 2 Diabetes Mellitus Patients: A Quantitative Susceptibility Mapping Study.

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Association of Iron and Myelin Alterations in the Contralesional Dentate Nucleus and Thalamus With Functional Outcome in Acute Ischemic Stroke: A Susceptibility Source Separation Study.

Journal of magnetic resonance imaging : JMRI·2026
Same journal

A Quantitative Modification of VI-RADS for Bladder Cancer at the Ureteral Orifice: A Reader Study on MRI With Varying Experience Levels.

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Editorial for "Integrating nnU-Net Segmentation and Clinical-Radiomics for Multicenter Prediction of Soft Tissue Sarcoma Grade and Ki-67 Expression".

Journal of magnetic resonance imaging : JMRI·2026
Same journal

Structural MRI Volumetry Index for Differentiation of Progressive Supranuclear Palsy From Parkinson's Disease and Multiple System Atrophy by Automatic Segmentation: A Comparison With Magnetic Resonance Parkinsonism Index.

Journal of magnetic resonance imaging : JMRI·2026
See all related articles

Gadolinium-enhanced 3D MR angiography (CE MRA) offers safe and accurate diagnosis of vascular diseases. Optimizing CE MRA involves precise timing of gadolinium injection and advanced MR techniques for improved imaging quality and reduced artifacts.

Area of Science:

  • Medical Imaging
  • Radiology
  • Cardiovascular Imaging

Background:

  • Contrast-enhanced Magnetic Resonance Angiography (CE MRA) is crucial for diagnosing vascular diseases.
  • Optimizing CE MRA requires understanding the interplay of gadolinium (Gd) injection timing, 3D MR data acquisition, and various imaging parameters.
  • Key factors include resolution, coverage, and motion artifact sensitivity.

Purpose of the Study:

  • To detail the optimization of CE MRA techniques for improved diagnostic accuracy.
  • To highlight the critical role of gadolinium bolus timing in relation to k-space acquisition.
  • To discuss advanced MR techniques that enhance CE MRA performance.

Main Methods:

  • Utilizing gadolinium (Gd) contrast agent with 3D MR data acquisition.

Related Experiment Videos

  • Optimizing Gd injection timing to coincide with central k-space data acquisition.
  • Employing k-space oversampling for rapid 3D reconstructions and temporal resolution.
  • Leveraging parallel imaging to increase resolution and reduce scan time.
  • Implementing stepping table technology and thigh compression for whole-body MRA.
  • Main Results:

    • Accurate contrast arteriography is achievable with Gd-enhanced 3D MR data acquisition.
    • Precise timing of the gadolinium bolus peak with central k-space acquisition is critical for image contrast.
    • Oversampling k-space enables time-resolved imaging of the contrast bolus.
    • Parallel imaging minimizes motion and timing artifacts while shortening scan times.
    • Whole-body MRA is feasible with a single contrast injection.

    Conclusions:

    • CE MRA is a safe, fast, and accurate method for diagnosing vascular diseases.
    • Advancements in MR technology are continually improving the performance and simplicity of CE MRA.
    • CE MRA's efficacy in diagnosing and managing vascular diseases is increasing.