Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
The influence of grafted polymer architecture and fluid hydrodynamics on protein separation by entropic interaction
Bryan R Coad1, Bradley M Steels, Jayachandran N Kizhakkedathu
1The Centre for Blood Research, the Department of Chemistry, University of British Columbia, Vancouver, BC, Canada V6T 1Z4.
Abstract:
Entropic interaction chromatography (EIC) provides efficient size-based separation of protein mixtures through the entropy change associated with solute partitioning into a layer of hydrophilic homopolymer that has been end-grafted within the pores of a macroporous chromatography support. In this work, surface-initiated atom-transfer radical polymerization (ATRP) is used to prepare a library of EIC stationary phases covering a wide range of grafted-chain densities and molecular weights. Exhaustive chain cleavage and analysis by saponification and GPC-MALLS, respectively, show that the new ATRP synthesis procedure allows for excellent control over graft molecular weight and polydispersity. The method is used to prepare high-density grafts (up to 0.164 +/- 0.005 chains/nm(2)) that extend the range of EIC applications to include efficient buffer-exchange and desalting of protein preparations. Reducing the graft density allows for greater partitioning of high molecular weight solutes, extending the linear range of the selectivity curve. Increasing graft molecular weight also alters selectivity, but more directly affects column capacity by increasing the volume of the grafted layer. Protein partitioning in high-density EIC columns is found to decrease with mobile-phase velocity (u). Although solute mass transfer resistances leading to an increase in plate height can explain this effect, pressure drop data across the column are indicative of weak convective flow through at least a fraction of the grafted architecture. Modeling of the grafted brush properties in the presence of solvent flow by subjecting a self-consistent-field theory representation of the brush to a viscous shear force predicts that the grafted chains will tilt and elongate in the direction of flow. The shear force may therefore act to reduce the number of conformations available to chains, increasing their rigidity without significantly altering the thickness of the grafted layer. A reduction in protein partitioning is then predicted when the dependence on u of the solute entropy loss is stronger than that of the grafted polymer, a condition met at high graft densities.
Related Concept Videos
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Affinity Chromatography
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...