Related Experiment Video
Updated: Jul 18, 2026

11:58
Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms
Published on: August 11, 2015
A standardized method to create optic nerve crush: Yasargil aneurysm clip.
Levent Sarikcioglu1, Necdet Demir, Arife Demirtop
1Department of Anatomy, Akdeniz University, Faculty of Medicine, 07070 Antalya, Turkey. sarikcioglu@akdeniz.edu.tr
Experimental Eye Research
|December 13, 2006
Summary
Comparing nerve compression injury studies is challenging due to varied methods. This study introduces a standardized device for crushing the optic nerve, enabling more reliable interlaboratory comparisons of nerve compression research.
Area of Science:
- Neuroscience
- Biomedical Engineering
Background:
- Nerve compression injuries present a significant challenge in research.
- Inconsistent methodologies and pressure levels hinder the comparison of study results across different laboratories.
Purpose of the Study:
- To address the lack of standardization in nerve compression injury research.
- To introduce a novel, reproducible method for inducing optic nerve compression.
Main Methods:
- Development and utilization of a specially designed, commercially available device for optic nerve crushing.
- Focus on standardizing the application of pressure to the optic nerve.
Main Results:
- A new, reproducible method for optic nerve compression was successfully established.
- The developed device allows for consistent and comparable pressure application.
Conclusions:
- Standardization of compression methods is crucial for reliable interlaboratory comparisons in nerve compression injury research.