Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Effects of steady state free precession parameters on cardiac mass, function, and volumes
Maureen C Hogan1, Steffen E Petersen, Lucy E Hudsmith
1University of Oxford Centre for Clinical Magnetic Resonance Research, Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU, UK.
Purpose:
We aimed to investigate comparability of LV volumes, function, and mass acquired with three steady-state free precession (SSFP) pulse sequences, simulating typical vendor and protocol specific differences in data acquisition.
Methods:
Twenty-one healthy subjects (11 male and 10 female; age range 23-49) underwent cardiac magnetic resonance (CMR) imaging at 1.5 Tesla (T). A complete stack of short-axis views covering the entire left ventricle (LV) were acquired for each of the three SSFP sequences, differing in the interslice gap and slice thickness (7 mm with no gap (7/0 mm); 7 mm with a 3 mm gap (7/3 mm) and 6 mm with a 4 mm gap (6/4 mm)) with slight variations in acquisition parameters. For each sequence, the LV volumes, function, and mass were determined. Intra- and inter-observer variability and inter-study reproducibility were assessed for all protocols.
Results:
All LV volumes, function and mass parameters were similar for the three SSFP sequences (P > 0.05 for all). The LV ejection fraction for the 7/3 mm sequence was 67.2 +/- 6.0, 67.4 +/- 5.3 for the 7/0 mm sequence, and the 6/4 mm sequence was 69.2 +/- 5.7. The LV mass ranged from 119.8 +/- 32.4 for the 7/3 mm sequence to 122.2 +/- 34.0 for the 7/0 mm sequence. Variabilities were low with no difference in variability between the sequences.
Conclusion:
The three SSFP pulse sequence techniques resulted in similar LV volume, function, and mass measurements with no difference in observer and interstudy variabilities. This may allow application and transfer of LV volume studies and databases based on different imaging parameters, at different CMR sites, with a given post-processing method. Future multi-centre studies may now be in a position to consider multi-vendor study designs for LV volume studies.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Pathophysiology of Cardiac Performance
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...