Study on the radial composite piezoelectric ceramic transducer in radial vibration
1Institute of Applied Acoustics, Shaanxi Normal University, Xian, Shaanxi 710062, PR China. sxsdsxs@snnu.edu.cn <sxsdsxs@snnu.edu.cn>
Abstract:
A new type of radial composite piezoelectric transducer in radial vibration is developed and analyzed. The radial composite transducer consists of a piezoelectric ceramic thin ring polarized in the thickness direction and a metal thin circular ring. They are connected together and excited to vibrate in the radial direction. The radial vibrations of a piezoelectric ceramic thin ring and a metal thin circular ring are analyzed, respectively. Their radial electro-mechanical equivalent circuits are obtained. Based on the electro-mechanical equivalent circuits and using the boundary conditions between the piezoelectric ceramic thin ring and the metal thin circular ring in the radial direction, the electro-mechanical equivalent circuit of the radial composite piezoelectric transducer is derived out and the resonance frequency equation is obtained. The relationship between the resonance frequency and the geometrical dimensions of the transducer is analyzed. Some radial composite piezoelectric transducers are designed and manufactured. The resonance frequencies and the anti-resonance frequencies, the electro-mechanical equivalent circuit parameters are measured. The effective electro-mechanical coupling coefficient and the mechanical quality factor are calculated. It is illustrated that the measured radial resonance frequencies are in good agreement with the theoretical results from the resonance frequency equation.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: