Design and Development of a Model to Study the Effect of Supplemental Oxygen on the Cystic Fibrosis Airway Microbiome
Published on: August 3, 2021
Effects of perfluorochemical evaporative properties on oxygenation during partial liquid ventilation
Mei-Jy Jeng1, Shyh-Sheng Yang, Betau Hwang
1Department of Pediatrics, Taipei Veterans General Hospital, Taichung, Taiwan. mjjeng@vghtpe.gov.tw
Background:
The physical-chemical properties of perfluorochemical (PFC) liquids have been shown to influence physiological and cellular responses during partial liquid ventilation (PLV). The aim of this study is to compare the relationship between patho-physiological endpoints and the physical properties of three PFC liquids used in treating acute lung injury.
Methods:
A total of 18 juvenile rabbits were randomized into conventional mechanical ventilation or PLV groups after lung saline lavages. Three PFC liquids, including Flutec perfluoro-1,3,5-trimethylcyclohexane (PP4; vapor pressure, 28.8 mmHg at 37 degrees C), Perfluorodecalin (PFD; vapor pressure, 13.6 mmHg at 37 degrees C), and Perflubron (PFB; vapor pressure, 10.4 mmHg at 37 degrees C) were used for PLV with no replacement for 4 h. A thermal detector was used to measure PFC loss rate. Physiological measurements and evaporative loss rate of PFC were done every 30 min, and lung histology was examined.
Results:
The mean evaporative loss rate was significantly higher in the PP4 group (4.75 +/- 0.24 mL/kg per h) than in either the PFD (1.43 +/- 0.11 mL/kg per h) or the PFB (1.18 +/- 0.05 mL/kg per h) group (P < 0.05). The oxygenation of PFD and PFB was maintained good for 4 h, however, the PP4 group showed a fast deterioration since 2 h post-treatment due to fast dropping of the residual PP4 amount in lungs. Histology showed good alveolar integrity in the PFD and PFB groups.
Conclusions:
The effects of PLV are directly influenced by the evaporative property of the PFC liquid. With no replacement over 4 h, PLV effects could be maintained with utilizing a PFC liquid with low, rather than high, vapor pressure. PFC with high vapor pressure has a high loss rate and low residual volume that causes poor maintenance on oxygenation during PLV. Therefore, measuring PFC loss rate is important in future studies and clinical application of PLV.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...