Related Experiment Video
Updated: Jul 18, 2026

A Simple and Inexpensive Method for Determining Cold Sensitivity and Adaptation in Mice
Published on: March 17, 2015
A cold-response index for the assessment of Raynaud's phenomenon
John Foerster1, Anja Kuerth, Eyline Niederstrasser
1Klinik für Dermatologie, Charité, Charitéplatz 1, 10117 Berlin, Germany. john.foerster@charite.de
Background:
Quantification of Raynaud's phenomenon (RP) is a prerequisite in the evaluation of novel therapeutic strategies. Fingertip rewarming in response to local cold provocation has been used in many studies but not been systematically validated. We have previously described the time elapsed before 63% of pre-cooling temperature is reached as a RP activity index.
Objective:
A comprehensive evaluation of fingertip rewarming in primary and scleroderma-associated RP.
Methods:
We defined a cold-response index (CRI) as the log transformation of the 63% rewarming time upon cold challenge.
Results:
The CRI shows high intra-individual reproducibility. The mean CRI values were (mean+/-S.D.): 2.4+/-0.3 in controls (n=53) versus 2.7+/-0.3 in RP (n=50, p<0.0001 versus controls), and 2.7+/-0.3 in scleroderma patients (n=46, p<0.0001). In addition, baseline fingertip temperature was also found to be significantly reduced both in primary as well as scleroderma-associated RP. Kinetic analysis of rewarming temperature curves demonstrates that the CRI is independent of individual rewarming patterns. Finally, the CRI decreases significantly upon a single low-level systemic hyperthermia treatment in scleroderma patients (2.68+/-0.28 before versus 2.45+/-0.33 after, p=0.0003), while the extent of cooling remained unchanged, thus demonstrating sensitivity to change.
Conclusion:
Our results provide a solid basis for using the cold-response assay as an endpoint in addition to clinical activity scores in RP treatment trials.
Related Concept Videos
Responses to Heat and Cold Stress
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
